Mini-Chillers and Ductless H2O mini-split fan coils
 

1source2buy is an authorized wholesale and retail distributor. If you need help planning a chiller system, press the sales help button below and we will assist you, or give us a call.

Also available are: mini-splits - spacepak high velocity

 
 

SpacePak® - Heat Pump Chiller - Contractor/Self-Contractor Pricing

The NEW 3 and 5-Ton 2-Stage Reverse Cyle Heat Pump Chillers. Self diagnostics, quiet operation 56db, R410A refrigerant, 208-230 Volts, 1 Phase, durable baked enamel finish, low amperage requirements. For more information, email us, or call sales at (813) 977-5286.

Model
Tons
Volts
Dimensions(HxWxL)
Price
Purchase
SCM036A4
3.0
208-230/1
53 x 43-1/4 x 17-1/4
$4907.00
Quantity Desired:
SCM060A4
5.0
208-230/1
53 x 43-1/4 x 17-1/4
$6234.00
Quantity Desired:
Literature
INSTALLATION/OPERATION/MAINTENANCE
SPEC SHEET

 
 

Other Chillers

Aermec
Aqua Products
5-20 Ton cooling only and heat pump chillers Many styles available from cool only to heat pump in sizes from 1.5-Tons and Up. Efficiency options available too.
SpacePak
Legacy
3 and 5-Ton Self Contained 2-Stage Heat Pump Chillers
Commercial - many options and styles available

Chilled/Heated Water Fan Coils

FirstCo
Lanco/Williams
Console floor mount, concealed ducted hideaway, Ductless ceiling/floor, Ducted conventional, ducted variable speed conventional Console floor mount, concealed ducted hideaway, Ductless ceiling/floor, Ducted conventional
SpacePak
Aermec
High velocity ducted
Hi-Wall ductless, concealed

 

DX R410a Fan Coils - Multi Position

Multi-position DX Cooling and heat pump Fan Coil. DX R410a refrigerant versions available. Mounts on wall, near floor, or on ceiling, pointing down horizontally. Cool/Heat versions are equipped with 24 volt terminal strips, so a wall mounted wired-in thermostat could be used. For more information or pricing, email us, or call sales at (813) 977-5286. Full line catalogs are available upon request.

Model#
Capacity
Volts
Heat kW
Application
Price
18DFCH
1.5-Ton
115 or 230
0kW or 2.5kW
DX Cooling or Heat Pump
Contact Us
24DFCH
2.0-Ton
115 or 230
0kW, 2.5kW or 5kW
DX Cooling or Heat Pump
Contact Us
30DFCH
2.5-Ton
115 or 230
0kW, 2.5kW or 5kW
DX Cooling or Heat Pump
Contact Us

 

Chilled Water Fan Coils - High Wall

High-wall mounted Fan Coil. Chilled/Hot Water. Optional electric heat. Mounts on wall, near ceiling, pointing down horizontally. Includes wire-less infrared remote control for all functions. A full function electronic wired control is also available as an option. For more information or pricing, email us, or call sales at (813) 977-5286. Full line catalogs are available upon request.

Model#
Capacity
Volts
# Pipes
Heat kW Option
Price
SWB-06
6,179
230
2
1kW
Contact Us
SWB-09
7,204
230
2
1.2kW
Contact Us
SWB-12
8,945
230
2
1.2kW
Contact Us
SWB-18
15,773
230
2
1.6kW
Contact Us

 

Chilled Water Fan Coils - Ceiling Concealed Hideaway

Ceiling concealed hideaway Fan Coil. Many styles available from basic to models bare bones and also with return air plenum and enclosure with return filter grille on the bottom. Mounts in closet, ducted right out in to the area, or concealed above the ceiling if a housing is made around the unit. Includes 24 volt terminals and relays for hooking up a wired-in wall mounted thermostat. 208-230 volts except as noted. For more information or pricing, email us, or call sales at (813) 977-5286. Full line catalogs are available upon request.

Model#
Capacity
Volts available
Heat Available Kw
# Pipes
Price
 
1-Ton
115 or 230
0 or 2 for 115|0,3,5,6,8 on 230
2 Contact Us
 
1.5-Ton
115 or 230
0 or 2 for 115|0,3,5,6,8 on 230
2 Contact Us
 
2-Ton
115 or 230
0 or 2 for 115|0,3,5,6,8 on 230
2 Contact Us
 
2.5-Ton
115 or 230
0 or 2 for 115|0,3,5,6,8 on 230
2 Contact Us
 
3-Ton
115 or 230
0 or 2 for 115|0,3,5,6,8 on 230
2 Contact Us
 
1-Ton
115 or 230
Hot Water
4 Contact Us
 
1.5-Ton
115 or 230
Hot Water
4 Contact Us
 
2-Ton
115 or 230
Hot Water
4 Contact Us
 
2.5-Ton
115 or 230
Hot Water
4 Contact Us
 
3-Ton
115 or 230
Hot Water
4 Contact Us

 

Chilled Water Fan Coils - Ducted

The water cooled/heated ducted fan coils for multi-position applications in closet, attic, garage, or basement. Electric heat strips are optional on all sizes and are indicated as the -XX part of the model number. Just replace -XX with the heat strip size needed. Upflow, horizontal right to left and convertable to left to right. 208-240 volts AC, 60 Hz, 1 phase. just like a typical ducted air-handler. For more information or pricing, email us, or call sales at (813) 977-5286. Full line catalogs are available upon request.
Model#
Capacity Tons
Electric Heat Options
Filter Size
Fan Speeds # Pipes
  1.5 0, 5, 8, 10 KW 16x20x1 3 2
  2.0 0, 5, 8, 10 KW 16x20x1 3 2
 
3.0
0, 5, 8, 10 KW
20x20x1
3 2
 
4.0
0, 5, 8, 10 KW
20x25x1
3 2
 
5.0
0, 5, 8, 10 KW
20x25x1
3 2
  2.0 Hot Water 16x20x1 3 4
 
3.0
Hot Water
20x20x1
3 4
 
4.0
Hot Water
20x25x1
3 4
 
5.0
Hot Water
20x25x1
3 4

 

Chilled Water Fan Coils - Console Floor Mount

The chilled/heated water ductless fan coils for floor mount applications. Many styles of cabinets available. For more information or pricing, email us, or call sales at (813) 977-5286. Full line catalogs are available upon request.
Model#
Capacity Tons
Electric Heat Options
Filter Size
Fan Speeds # Pipes
  1.5 0, 5, 8, 10 KW 16x20x1 3 2
  2.0 0, 5, 8, 10 KW 16x20x1 3 2
 
3.0
0, 5, 8, 10 KW
20x20x1
3 2
 
4.0
0, 5, 8, 10 KW
20x25x1
3 2
 
5.0
0, 5, 8, 10 KW
20x25x1
3 2
  2.0 Hot Water 16x20x1 3 4
 
3.0
Hot Water
20x20x1
3 4
 
4.0
Hot Water
20x25x1
3 4
 
5.0
Hot Water
20x25x1
3 4

 

Chilled Water Fan Coils - Concealed In-Wall

The chilled/heated water ductless in-wall recessed fan coil 2-pipe and 4-pipe versions available. For more information or pricing, email us, or call sales at (813) 977-5286. Full line catalogs are available upon request.
Model#
Capacity Tons
Electric Heat Options
Filter Size
Fan Speeds # Pipes
  1.5 0, 5, 8, 10 KW 16x20x1 3 2
  2.0 0, 5, 8, 10 KW 16x20x1 3 2
 
3.0
0, 5, 8, 10 KW
20x20x1
3 2
 
4.0
0, 5, 8, 10 KW
20x25x1
3 2
 
5.0
0, 5, 8, 10 KW
20x25x1
3 2
  2.0 Hot Water 16x20x1 3 4
 
3.0
Hot Water
20x20x1
3 4
 
4.0
Hot Water
20x25x1
3 4
 
5.0
Hot Water
20x25x1
3 4

 

 

Aerosys H2O - Ducted

Units are factory new. 115 or 230 Volts. Chilled Water ducted fan coils. The DCW Series of chilled water air handlers are designed to operate with centrally supplied chilled water source. Units are rated for use with 42ºF, 45ºF and 48ºF entering water temperatures in the cooling mode. These systems can also be used as a heating system when supplied with hot water instead of the chilled water. Units are rated for use with inlet hot water temperatures from 120ºF to 180ºF. These units are not recommended for leaving air temperatures over 140ºF. Low RPM blowers provide quiet operation, Multi 3-speed motors are field selectable for the application requirements, Powder coated cabinet for a durable finish. For more information or pricing, email us, or call sales at (813) 977-5286.

No Image Available
Model
Cooling Capacity 45° Water
Heating Capacity 140° Water
Dimensions HxWxD
Price
Purchase
DCW-20
22,000
36,000
29x24x14
$569.00
Quantity Desired:
DCW-26
27,000
45,000
33x24x14
$600.00
Quantity Desired:
DCW-32
30,000
54,300
34.75x29x15
$652.00
Quantity Desired:
 

Chiller Accessories

These are the common installation accessories for a chiller system. For more information or pricing, email us, or call sales at (813) 977-5286.. Full line catalogs are available upon request.

Part#
Description
Price Purchase
MZV524E-T
Honeywell Sparco 1/2" 2-way Zone Valve, 24VAC, threaded, auxiliary switch $121
Quantity Desired:
MZV525E-T
Honeywell Sparco 3/4" 2-way Zone Valve, 24VAC, threaded, auxiliary switch $121
Quantity Desired:
MZV526E-T
Honeywell Sparco 1" 2-way Zone Valve, 24VAC, threaded, auxiliary switch $130
Quantity Desired:
1500/1" Amtrol Expansion Tank Assembly Containing #15 Extrol tank, #700 air vent, #443 air purger 1". Use 1" or thicker ARMAFLEX insulation sheet. $115
Quantity Desired:
WX202H 20 Gallon Storage Tank. Horizontal tank space saver model with two 1" NPT fittings for inlet and outlet purposes. Bladder has also been removed. Use 1" or thicker ARMAFLEX insulation sheet. $286
Quantity Desired:
WX422H 42 Gallon Storage Tank. Horizontal tank space saver model with two 1.25" FNPT fittings for inlet and outlet purposes and 1" NPT plug. Bladder has also been removed. Use 1" or thicker ARMAFLEX insulation sheet. $665
Quantity Desired:
D146M1032 Honeywell Braukman 3/4" Bypass Valve w/ dial adjustment $159
Quantity Desired:
D146M1040 Honeywell Braukman 1 1/4" Bypass Valve w/ dial adjustment $223
Quantity Desired:
T513 Erie Rotary Heat/Cool, 3 speed fan, Ht/Off/CL 24 Volt $80
Quantity Desired:
SSP-1 1/2 HP Enclosed Stainless Steel circulator pump 1-60-115/230 $511
Quantity Desired:
1MS1E4CO 1 HP Enclosed Stainless Steel circulator pump 1-60-115/230 $555
Quantity Desired:
1MS1F4BO 1-1/2 HP Enclosed Stainless Steel circulator pump 1-60-115/230 $629
Quantity Desired:
1MS1G2AO 2 HP Enclosed Stainless Steel circulator pump 1-60-115/230 $695
Quantity Desired:

 
 
 

Mini-Chiller Benefits

No Refrigerant Handling
No Ductwork
No need to charge with refrigerant. The closed refrigerant system does away with the need for installation technicians that are certified to handle refrigerants. Because there are no refrigerant lines, installation costs are lower vs standard split systems. Cooling and heating with chilled water means running small, flexible, water pipes into the space within the walls, directly to the indoor chilled-water fan coils, without giving up hundreds of square feet of useable or living space to ductwork.
0% Duct Loss
Adjustable Water Temperature
Because insulated water lines carry the cooling capacity in the system. This is a more efficient unit delivering rated capacity to all of the conditioned spaces day after day.
Chillers are preset with water temperature at 44°F and can be adjusted down to 40°F water temperature, or up higher if desired.
Zoned Cooling And Heating
Ultra High Efficiency
With chilled water fan coils, you condition only the spaces you designate -not the whole house as opposed to a traditional central system. This fact allows for diversity and load shifting (For example, 10 tons of indoor coils may be hooked up to a 5 Ton chiller.) when doing load and sizing calculations, initially reducing installed cost as well as operating costs for years to come.
The Chiller contains the Copeland Compliant Scroll, simply the most efficient, quiet, reliable compressor available. If you already have a chilled water system and just need to add on, or replace current fan coils, we have many styles of fan coils will work.
Fan Coils
.
The Non-ducted Fan Coils -  have worldwide recognition for quiet, reliable operation and have a reputation for sleek, seamless design. These chilled water fan coils can be operated from a central thermostat or can have individual controls, infrared remotes or hard-wired controls. Sizes are available from 9,000 BTU to 60,000 BTU. .

What You Will Need

Chiller/SpacePak Chiller
Fan Coils
The heart of the chilled water system. This is where the cooling of the water takes place. In the heat-pump version, heating also takes place inside this unit. The chiller can be located a distance away from the main structure to reduce sound levels inside. Just be sure to accurately account for the extra pressure loss due to using longer runs of pipe. The circulation pump is also inside this unit. Be sure the use the proper percentage of glycol in the water loop to prevent freezing The wall mounted fan coils come standard with a wireless remote control for each unit. From the remote, you can control temperature, fan speed, vane direction and cooling/off/heat mode. There are also universal mount fan coils that can mount low on the wall, near the floor, or up on the ceiling. Also, the ceiling concealed hide-away fan coil is perfect for installing in a closet, or dropped ceiling. SpacePak high velocity fan coils have been very successful with chiller installations. If you need a different type of fan coil, just let us know what you are looking for and we will present you with all the available options in fan coils.
Tubing
Solenoid Valves
Use either copper tubing with insulation, or composite tubing, such as Vanguard PEX, or KITEC with a built-in vapor barrier. Just remember that your supply and return tubing needs to be insulated.
These electronically control the flow of cooled or heated liquid solution to each fan coil. Each fan coil needs to have an electronic solenoid valve. 3-way solenoid valves are preferred over two way valves, because you can keep system pressures fairly constant by sending water to the return line when the fan coil is not calling for cool or heat.
Bypass Valve
Expansion Tank
This is used to relieve system pressure from the supply to the return, as system fan coil valves are opened and closed. This valve should be installed near the beginning of the water loop, close to the chiller. In addition to a bypass valve 3-way solenoid valves are recommended over 2-way valves.
Used to compensate for the expansion and contraction of liquid in the system. The included air-scoop eliminates air entrained in the system. In addition to the air removal in the expansion tank, you will also need to be certain that you bleed the air from all the bleeder valves in the entire system during the initial start-up, or pump failure will occur.
Storage Tank
.
This is used in systems that will contain a total of less than 25 gallons of liquid solution. The tank prevents rapid cycling of the compressor. It must also be insulated. Use 25 gallons minimum for 3 and 4-ton systems and use 25-30 gallons of storage per 5-tons. .