P474-1010
and P474-0100 |
TSTATCCPB501,
P474-1050 , 33CSSN2-FC, 33CSSP2-FC |
TB-PAC01
and TB-PHP01 |
|
 |
P474-1010
- Programmable, auto-changeover, "Thermoglow"
continuously lit Electro-luminous display, Display shows
both heating and cooling setpoints and room temperature
simultaneously, 5-min compressor protection, Dual-setpoint
with adjustable deadband, setpoint adjustment range from
35° to 99°F, switchable to Celsius, hard wire or
power stealing, 2-color LED for status. Green for cool and
red for heat. 4 time periods for programming, 1-year limited
warranty. Learn
More |
 |
P474-0100
- Non-Programmable, Dual-setpoint with adjustable deadband,
setpoint adjustment range from 35° to 99°F, 1 or
2 stage heat. auto-changeover, "Thermoglow" continuously
lit Electro-luminous display, 5-min compressor protection,
hard wire or power stealing, 2-color LED for status. Green
for cool and red for heat. 1-year limited warranty. Learn
More |
 |
TSTATCCPB501 or P474-1050 Programmable,
1 or 2 stage cool, 1 or 2 stage heat. auto-changeover, "Thermoglow"
continuously lit Electro-luminous display, Display shows
both heating and cooling setpoints and room temperature
simultaneously, 5-min compressor protection, Dual-setpoint
with adjustable deadband, setpoint adjustment range from
35° to 99°F, switchable to Celsius, hard wire or
power stealing, 2-color LED for status. Green for cool and
red for heat. 4 time periods for programming, 1-year limited
warranty. Learn
More |
 |
TB-PAC01
- for 1-stage cool, 1-stage heat systems. TB-PHP01 for heat
pump systems. Battery and/or 24VAC Hard-wired power. Backlighting,
HP model can be set for AC or HP. 4 time periods for programming
(morning, day, evening, night), weekdays and weekends have
different time and temp schedule. 5-minute compressor protector,
Cycle Timer, minimum on timer, staging timer. HP model has
aux heat indicator. 1-year limited warranty. |
 |
33CSSN2-FC
- 2 or 4 pipe fan coils, 24-volt power, 3 speed fan operation,
single or dual setpoint, continuously lit thermo-glow display,
heating and cooling color changing indicator light, 1 degree
accuracy, keypad lock, dry contact with normally open or
closed option, outside air temp display option, display
blanking feature, auto change-over, included optional Exact
fit locking cover with tamper proof screws and keyed access,
35°F-99°F temperature setting range, adjustable
deadband between 1°F and 6°F, 1-year limited warranty.
Learn
More |
 |
33CSSP2-FC
- Same as 33CSSN2-FC above, but features 7 day programming
with 4 periods per day. Learn
More |
 |
33ZCRLYBRD
- Fan Coil Relay Board. Eliminates the requirements to install
individual control relays for fan speeds and line voltage
valves. Interface to either 3 fan speeds or 2 line voltage
valves . Small footprint allows easy installation . Quick
connect 1/4-in. male type crimp lugs for line voltage connections.
Carrier's HVAC Controls 33ZCRLYBRD fan coil relay board
matches to low voltage fan coil thermostats to provide the
line voltage control if low voltage terminals are not on
your fan coil. Learn
More |
|
| Cool
Stages |
Heat
Stages |
Model |
Price |
Buy |
| 1
or 2 |
1
or 2 |
P474-1010 |
$44.00 |
|
| 1
or 2 |
1
or 2 |
P474-0100
[non-programmable] |
$44.00 |
|
| 1
or 2 |
1
or 2 |
| TSTATCCPB501
[Carrier] |
| TSTATBBPB501 |
| P474-1050
[Totaline] |
|
$51.00 |
|
| 1 |
1 |
TB-PAC01 |
$58.00 |
|
| 1 |
1
or 2 |
TB-PHP01 |
$66.00 |
|
| 2
or 4 pipe 24 volt fan coil control. |
2
or 4 pipe 24 volt fan coil control. |
33CSSN2-FC |
$101.00 |
|
| 2
or 4 pipe 24 volt fan coil control. |
2
or 4 pipe 24 volt fan coil control. |
33CSSP2-FC |
$120.00 |
|
| 3
speed fan |
3
speed fan |
33ZCRLYBRD |
$74.00 |
|
|
|