SpacePak, Spacepak, High velocity, mini-duct, miniduct, mini duct, Unico
SpacePak, Spacepak, High velocity, mini-duct, miniduct, mini duct, Unico
 
   
Spacepak, Space Pak, High velocity, High-velocity
SpacePak® mini-duct high velocity
Spacepak, mini-duct, mini-ducts, mini duct, mini ducts
 

Listed below is a rough estimate of the number of outlets needed and the square footage associated with it. Figure that corner rooms are WEST exposure. These estimates are for an 8' ceiling height. Remember this is just an estimate. To get an accurate determination, make sure you go through the complete sizing worksheet.

Also available: SpacePak Equipment - 13-18 SEER Air Conditioners - 13-17 SEER Heat-Pumps - Boilers - Water Chillers

 
Spacepak high velocity mini-duct systems
 
ESP-2430D, ESP-3642D, ESP-4860D, ESP-2430-V, ESP-3642-V, ESP-4860-V,
SpacePak, Space Pak, mini-duct, mini duct, high velocity, 

SpacePak® - Estimated Room Sizer

SpacePak ESP-V, ESP-2430-V, ESP-3642-V, ESP-4860-V, Vertical high velocity mini-duct air handlerUse the following as a guide for planning and selecting the equipment you will need for a successful SpacePak system. Figure that rooms on a corner are west exposure. This is for 8' ceiling heights. Remember this is an estimate only and nothing will take the place of completing the complete sizing worksheet. If you still need more help, please send us an email, or call us up for some help.

 
North Exposure
East Exposure
South Exposure
West Exposure
10x10
1
1.5
1.5
1.5
10x14
2
2
2
2
12x10
1.5
1.5
1.5
2
12x16
2
2
2
2.5
12x20
2.5
2.5
2.5
3
14x12
2
2
2
2.5
14x16
2.5
3
3
3
14x20
2.5
3.5
3.5
3.5
16x12
2
2.5
2.5
3
16x16
3
3
3
3
16x20
3.5
3.5
3.5
4
18x12
3
3
3
3
18x16
3
3
3
3.5
18x20
3.5
4
4
4
20x12
3
3
3
4
20x16
3
4
4
4
20x18
4
4
4
5
20x22
4
4
4
5

 

SpacePak® - Guidance/Reference Materials

SpacePak ESP-V, ESP-2430-V, ESP-3642-V, ESP-4860-V, Vertical high velocity mini-duct air handlerUse the following links to help you plan your SpacePak system correctly, or to view an installation movie. If you still need more help, please send us an email, or call us up for some help.

SpacePak ESP-V, ESP-2430-V, ESP-3642-V, ESP-4860-V, Vertical high velocity mini-duct air handler
SpacePak Brochure
Installation Movies and Sizing Calculators
Press Here To View
Planning Guide
Typical Equipment List
Complete Sizing Worksheet
Individual Room Sizing Estimator
Press Here To View
2430 Air Handlers (fully open outlets)
Round Plenum Layout Diagram
min 12 outlets for 2.0-ton system
Press Here To View
min 14 outlets for 2.5-ton system
Square Plenum Layout Diagram
total cfm = 550
3642 Air Handlers (fully open outlets)
3-5 & 10 Ton Chillers
min 17 outlets for 3.0-ton system Press Here To View
min 19 outlets for 3.5-ton system Zoning SpacePak Systems
total cfm = 850 Press Here To View
4860 Air Handlers (fully open outlets)
Replacement Parts
min 26 outlets for 4.0-ton system
min 26 outlets for 5.0-ton system Air Flow Design
total cfm = 1150 maintain 33-44 cfm per outlet.